{ "id": "CVE-2024-5659", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2024-06-14T17:15:51.600", "lastModified": "2024-06-17T12:42:04.623", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\u00a0If exploited, the availability of the device would be compromised." }, { "lang": "es", "value": "Rockwell Automation fue informado de una vulnerabilidad que hace que todos los controladores afectados en la misma red produzcan una falla importante no recuperable (MNRF/Assert). Esta vulnerabilidad podr\u00eda explotarse enviando paquetes anormales al puerto mDNS. Si se explota, la disponibilidad del dispositivo se ver\u00eda comprometida." } ], "metrics": { "cvssMetricV40": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "attackVector": "ADJACENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "NONE", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE", "vulnerableSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "subsequentSystemAvailability": "HIGH", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "baseScore": 8.3, "baseSeverity": "HIGH" } } ] }, "weaknesses": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-670" } ] } ], "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html", "source": "PSIRT@rockwellautomation.com" } ] }