{ "id": "CVE-2023-1049", "sourceIdentifier": "cybersecurity@se.com", "published": "2023-06-14T08:15:08.773", "lastModified": "2023-06-22T00:57:14.267", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.\n\n" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 }, { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-94" } ] }, { "source": "cybersecurity@se.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-94" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.3", "matchCriteriaId": "5705916B-E189-4314-AD32-C8D42991DFA2" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:-:*:*:*:*:*:*", "matchCriteriaId": "A6EAEC62-F689-43A2-8EDB-68867661ED92" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:sp1:*:*:*:*:*:*", "matchCriteriaId": "17F5EDCD-B9E6-40D7-88FC-C2685384C5B4" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.3", "matchCriteriaId": "297C4149-AA1F-4033-BD74-0FB908783399" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:3.3:-:*:*:*:*:*:*", "matchCriteriaId": "FB229476-7E0C-46ED-817D-C9A72250CC5D" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:3.3:sp1:*:*:*:*:*:*", "matchCriteriaId": "78D3C9DF-3354-47E0-881F-4B59CE22BCF7" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-01.pdf", "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ] } ] }