{ "id": "CVE-2023-20209", "sourceIdentifier": "ykramarz@cisco.com", "published": "2023-08-16T21:15:09.650", "lastModified": "2023-08-24T14:23:42.837", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability in the web-based management interface of Cisco Expressway Series and Cisco TelePresence Video Communication Server (VCS) could allow an authenticated, remote attacker with read-write privileges on the application to perform a command injection attack that could result in remote code execution on an affected device.\r\n\r This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted request to the web-based management interface of an affected device. A successful exploit could allow the attacker to establish a remote shell with root privileges." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.2, "impactScore": 5.9 }, { "source": "ykramarz@cisco.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.2, "impactScore": 5.2 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-77" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:cisco:telepresence_video_communication_server:*:*:*:*:*:*:*:*", "versionEndExcluding": "14.3.1", "matchCriteriaId": "0840F942-9484-461E-8F07-5691CD8E75DC" }, { "vulnerable": true, "criteria": "cpe:2.3:a:cisco:telepresence_video_communication_server:*:*:*:*:expressway:*:*:*", "versionEndExcluding": "14.3.1", "matchCriteriaId": "B55E57CE-7762-418D-B85D-19EF29429623" } ] } ] } ], "references": [ { "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-expressway-injection-X475EbTQ", "source": "ykramarz@cisco.com", "tags": [ "Vendor Advisory" ] } ] }