{ "id": "CVE-2023-31167", "sourceIdentifier": "security@selinc.com", "published": "2023-08-31T16:15:08.507", "lastModified": "2024-11-21T08:01:32.673", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal.\n\n\n\nSEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details.\n\n\nThis issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778.\n\n" } ], "metrics": { "cvssMetricV31": [ { "source": "security@selinc.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N", "baseScore": 5.0, "baseSeverity": "MEDIUM", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "availabilityImpact": "NONE" }, "exploitabilityScore": 1.3, "impactScore": 3.6 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "baseScore": 8.1, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.8, "impactScore": 5.2 } ] }, "weaknesses": [ { "source": "security@selinc.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-22" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:selinc:sel-5036_acselerator_bay_screen_builder:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.49152.778", "matchCriteriaId": "DDE78144-2332-4226-812D-675E8FB6EEFE" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA" } ] } ] } ], "references": [ { "url": "https://dragos.com", "source": "security@selinc.com", "tags": [ "Not Applicable" ] }, { "url": "https://selinc.com/support/security-notifications/external-reports/", "source": "security@selinc.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://dragos.com", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ] }, { "url": "https://selinc.com/support/security-notifications/external-reports/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }