{ "id": "CVE-2024-4872", "sourceIdentifier": "cybersecurity@hitachienergy.com", "published": "2024-08-27T13:15:05.890", "lastModified": "2024-10-30T15:31:41.743", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability\nan attacker must have a valid credential." }, { "lang": "es", "value": "El producto no valida ninguna consulta sobre datos persistentes, lo que genera riesgo de ataques de inyecci\u00f3n." } ], "metrics": { "cvssMetricV31": [ { "source": "cybersecurity@hitachienergy.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "baseScore": 9.9, "baseSeverity": "CRITICAL", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.1, "impactScore": 6.0 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 8.8, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "cybersecurity@hitachienergy.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-943" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf1:*:*:*:*:*:*", "matchCriteriaId": "0B90ED6E-68E4-4C14-B275-F44BAC1B9C5C" }, { "vulnerable": true, "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf2:*:*:*:*:*:*", "matchCriteriaId": "196E08EA-807C-4B7B-981A-96D106AC328B" }, { "vulnerable": true, "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf3:*:*:*:*:*:*", "matchCriteriaId": "680FAE83-9D7A-4AD9-AFBE-480FD105ADC9" }, { "vulnerable": true, "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf4:*:*:*:*:*:*", "matchCriteriaId": "014C8428-8F88-4C3D-B9B1-87DE26867471" }, { "vulnerable": true, "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf5:*:*:*:*:*:*", "matchCriteriaId": "06AFA271-0785-4526-B7DA-FA00672CC5B5" }, { "vulnerable": true, "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "versionStartIncluding": "10.0", "versionEndExcluding": "10.6", "matchCriteriaId": "AEAAFA90-ACFF-47E2-A23D-728912D74B99" } ] } ] } ], "references": [ { "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch", "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ] } ] }