{ "id": "CVE-2024-9409", "sourceIdentifier": "cybersecurity@se.com", "published": "2024-11-13T05:15:27.610", "lastModified": "2024-11-19T15:59:21.690", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network." }, { "lang": "es", "value": "CWE-400: Existe una vulnerabilidad de consumo descontrolado de recursos que podr\u00eda provocar que el dispositivo deje de responder y produzca p\u00e9rdida de comunicaci\u00f3n cuando hay una gran cantidad de paquetes IGMP en la red." } ], "metrics": { "cvssMetricV40": [ { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 8.7, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "NONE", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirement": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "availabilityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED" } } ], "cvssMetricV31": [ { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-400" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5341_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.7.0", "matchCriteriaId": "2C518E91-E251-4278-83D6-144B1CC6331F" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5341:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C575247-0AE3-408C-8154-71A256FD0292" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5340_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.4.0", "matchCriteriaId": "65E456CF-4247-4FB9-858D-6920EF946CF2" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5340:-:*:*:*:*:*:*:*", "matchCriteriaId": "F5C8EA2A-37CF-435F-A1ED-789255404CD6" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5320_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.4.0", "matchCriteriaId": "EB64AE9B-637D-48A5-AE98-6F120C7E355A" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5320:-:*:*:*:*:*:*:*", "matchCriteriaId": "47592B0C-9E15-4D4C-B284-F2390678E1AC" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf", "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ] } ] }