{ "id": "CVE-2022-32514", "sourceIdentifier": "cybersecurity@se.com", "published": "2023-01-30T23:15:10.007", "lastModified": "2023-02-08T16:55:22.903", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)" }, { "lang": "es", "value": "Existe una vulnerabilidad CWE-287: autenticaci\u00f3n incorrecta que podr\u00eda permitir a un atacante obtener control del dispositivo al iniciar sesi\u00f3n en una p\u00e1gina web. Productos afectados: Controlador de automatizaci\u00f3n de red C-Bus - LSS5500NAC (versiones anteriores a V1.10.0), Wiser para controlador de automatizaci\u00f3n de red C-Bus - LSS5500SHAC (versiones anteriores a V1.10.0), Controlador de automatizaci\u00f3n de red Clipsal C-Bus - 5500NAC (versiones anteriores a V1.10.0), Clipsal Wiser para controlador de automatizaci\u00f3n C-Bus - 5500SHAC (versiones anteriores a V1.10.0), controlador de automatizaci\u00f3n de red SpaceLogic C-Bus - 5500NAC2 (versiones anteriores a V1.10.0), controlador de aplicaciones SpaceLogic C-Bus - 5500AC2 (Versiones anteriores a V1.10.0)" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 }, { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-287" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:5500ac2:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E9DDB3B-9342-4729-9EE7-703426B9670C" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:5500ac2_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "matchCriteriaId": "E7628A67-6DD8-47B7-9112-C130AF0DA9BD" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:5500nac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDCFD29E-C66E-41F4-B578-095C08799994" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:5500nac_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "matchCriteriaId": "FD075DCC-90DA-45A1-ADC9-ADD7D984B2F9" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:5500nac2:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF623989-1FC8-44D5-9B4B-42CDCF31B824" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:5500nac2_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "matchCriteriaId": "E7B729EF-ECCC-41E1-BF89-E2EAB013144F" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:5500shac:-:*:*:*:*:*:*:*", "matchCriteriaId": "91E6F8C8-BC42-4EA0-B36F-96CCE73B080F" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:5500shac_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "matchCriteriaId": "D414788B-B8B5-41A0-8946-433D7A308F4D" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:lss5500nac:-:*:*:*:*:*:*:*", "matchCriteriaId": "0844B578-39C4-413F-9CE9-5DA12A02CE8A" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:lss5500nac_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "matchCriteriaId": "B1F807FA-B4A7-4917-80D9-1D9D3AA96516" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:lss5500shac:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B48CA89-FC26-45D4-91C3-F2BD74DC3FBC" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:lss5500shac_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "matchCriteriaId": "3B231797-8810-4C77-BD0B-0C8A6FBD8C2B" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf", "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }