{ "id": "CVE-2022-20744", "sourceIdentifier": "ykramarz@cisco.com", "published": "2022-05-03T04:15:09.437", "lastModified": "2024-11-26T16:09:02.407", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization." }, { "lang": "es", "value": "Una vulnerabilidad en los mecanismos de protecci\u00f3n de entrada del software Cisco Firepower Management Center (FMC) podr\u00eda permitir a un atacante remoto autenticado visualizar datos sin autorizaci\u00f3n apropiada. Esta vulnerabilidad se presenta debido a un mecanismo de protecci\u00f3n que es basado en la existencia o los valores de una entrada espec\u00edfica. Un atacante podr\u00eda explotar esta vulnerabilidad al modificar esta entrada para omitir el mecanismo de protecci\u00f3n y vulnerabilidad mediante el env\u00edo de una petici\u00f3n dise\u00f1ada a un dispositivo afectado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante visualizar datos m\u00e1s all\u00e1 del alcance de su autorizaci\u00f3n" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "baseScore": 6.5, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } ], "cvssMetricV30": [ { "source": "ykramarz@cisco.com", "type": "Secondary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "baseScore": 4.3, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.8, "impactScore": 1.4 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "baseScore": 4.0, "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "ykramarz@cisco.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-807" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*", "versionEndExcluding": "7.1.0", "matchCriteriaId": "F62A86D8-58DA-487A-BB48-30F4879AE9A3" } ] } ] } ], "references": [ { "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu", "source": "ykramarz@cisco.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }