{ "id": "CVE-2022-46670", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2022-12-16T21:15:09.040", "lastModified": "2024-11-21T07:30:52.580", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u00a0of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u00a0The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \n\n" }, { "lang": "es", "value": "Un investigador de seguridad del Instituto de Tecnolog\u00eda de Georgia inform\u00f3 a Rockwell Automation de una vulnerabilidad que indica que los controladores MicroLogix 1100 y 1400 contienen una vulnerabilidad que puede brindarle a un atacante la capacidad de realizar la ejecuci\u00f3n remota de c\u00f3digo. La vulnerabilidad es de Cross-Site Scripting almacenado, no autenticada en el servidor web integrado. El payload se transfiere al controlador a trav\u00e9s de SNMP y se representa en la p\u00e1gina de inicio del sitio web integrado." } ], "metrics": { "cvssMetricV31": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L", "baseScore": 7.1, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "LOW" }, "exploitabilityScore": 2.8, "impactScore": 3.7 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "baseScore": 6.1, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } ] }, "weaknesses": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-79" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-79" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "11507EFF-5C53-4217-9257-21936118C032" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*", "matchCriteriaId": "196EA0BE-FDF3-46BE-B3DA-5F49208C5D80" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCE86CDF-12CC-4B02-942D-BF9134218F2B" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA42C7F4-EEC1-44D2-BD46-237969FF6E1A" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-b_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "21.007", "matchCriteriaId": "E6C4D215-CB09-4BEA-89A6-2BAACD461FBE" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-b:-:*:*:*:*:*:*:*", "matchCriteriaId": "3D01BD0A-CA96-4882-8523-EC4D522DA4AF" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-c_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "21.007", "matchCriteriaId": "FD745E1D-10D9-4FD6-9F7C-63CB51F3C454" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-c:-:*:*:*:*:*:*:*", "matchCriteriaId": "DC9A2DE5-E745-4F1B-931C-E11814A7D23A" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-a_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "7.000", "matchCriteriaId": "2E2B3E77-CF64-4D7F-A849-5462CABB576D" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-a:-:*:*:*:*:*:*:*", "matchCriteriaId": "81AFED05-B927-4BF7-ABC5-5E3F7555593D" } ] } ] } ], "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679", "source": "PSIRT@rockwellautomation.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }