{ "id": "CVE-2024-23799", "sourceIdentifier": "productcert@siemens.com", "published": "2024-02-13T09:15:48.380", "lastModified": "2024-02-13T19:22:01.760", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones), Tecnomatix Plant Simulation V2302 (Todas las versiones < V2302.0007). Las aplicaciones afectadas contienen una vulnerabilidad de desreferencia de puntero nulo al analizar archivos SPP especialmente manipulados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para bloquear la aplicaci\u00f3n y provocar una condici\u00f3n de denegaci\u00f3n de servicio." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.8, "impactScore": 3.6 }, { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "LOW", "baseScore": 3.3, "baseSeverity": "LOW" }, "exploitabilityScore": 1.8, "impactScore": 1.4 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-476" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "versionStartIncluding": "2302.0", "versionEndExcluding": "2302.0007", "matchCriteriaId": "F1CA9BCC-60B4-44F3-9D13-82EE1E3D834A" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:2201.0:-:*:*:*:*:*:*", "matchCriteriaId": "ACE93AE4-565D-40A2-9954-DA02442AEDD1" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html", "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ] } ] }