{ "id": "CVE-2017-18734", "sourceIdentifier": "cve@mitre.org", "published": "2020-04-23T17:15:11.910", "lastModified": "2020-04-23T22:22:34.033", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.18, R6050 before 1.0.1.10, R6220 before 1.1.0.50, R6700v2 before 1.2.0.4, R6800 before 1.2.0.4, R6900v2 before 1.2.0.4, WNDR3700v5 before 1.1.0.48, WNR1000v4 before 1.1.0.44, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a JNR1010v2 versiones anteriores a 1.1.0.44, JR6150 versiones anteriores a 1.0.1.10, JWNR2010v5 versiones anteriores a 1.1.0.44, PR2000 versiones anteriores a 1.0.0.18, R6050 versiones anteriores a 1.0.1.10, R6220 versiones anteriores a 1.1.0.50, R6700v2 versiones anteriores a 1.2.0.4, R6800 versiones anteriores a 1.2.0.4, R6900v2 versiones anteriores a 1.2.0.4, WNDR3700v5 versiones anteriores a 1.1.0.48, WNR1000v4 versiones anteriores a 1.1.0.44, WNR2020 versiones anteriores a 1.1.0.44 y WNR2050 versiones anteriores a 1.1.0.44." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ], "cvssMetricV30": [ { "source": "cve@mitre.org", "type": "Secondary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "ADJACENT_NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 5.8 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 6.5, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-74" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0.44", "matchCriteriaId": "FC9E7939-E195-44AB-8880-D0BCF26BF2E0" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.1.10", "matchCriteriaId": "4B5D8AD4-6C67-4DC7-99DF-B29DBA4BC376" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0.44", "matchCriteriaId": "34429B2B-D8CB-4BEC-B5FA-5C7F8AC9A1FE" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.0.18", "matchCriteriaId": "6754FA98-E862-4C0B-9146-E858B15B0AE6" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.1.10", "matchCriteriaId": "CB4D669D-D6C4-403E-896D-55EE4EEB7C27" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0.50", "matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.2.0.4", "matchCriteriaId": "0EA5FF68-8609-4692-8DBF-A12606882BE5" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.2.0.4", "matchCriteriaId": "A272C3DA-043A-4621-9F16-70F9501FEE46" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.2.0.4", "matchCriteriaId": "8B89AB47-7117-4FA7-B8F1-36D0C281C403" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0.48", "matchCriteriaId": "DD1F416B-C938-4AE3-B93E-03087575FF40" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0.44", "matchCriteriaId": "E5684DEA-5F12-4E72-B8D1-C5F3E1D22726" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0.44", "matchCriteriaId": "36CCD48D-4474-4363-8DE6-846714B99D3D" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0.44", "matchCriteriaId": "436026D2-0B8E-4BA5-AD34-9EB285EDA78A" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C" } ] } ] } ], "references": [ { "url": "https://kb.netgear.com/000051521/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Extenders-PSV-2017-2154", "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ] } ] }