{ "id": "CVE-2017-6023", "sourceIdentifier": "ics-cert@hq.dhs.gov", "published": "2017-03-16T04:59:00.153", "lastModified": "2021-10-28T11:54:47.673", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device." }, { "lang": "es", "value": "Se ha descubierto un problema en Fatek Automation PLC Ethernet Module. Las herramientas de configuraci\u00f3n del software Ether_cfg afectado en las siguientes versiones de Fatek PLCs: CBEH anteriores a V3.6 Build 170215, CBE versiones anteriores a V3.6 Build 170215, CM55E versiones anteriores a V3.6 Build 170215 y CM25E versiones anteriores a V3.6 Build 170215. Se ha identificado un desbordamiento de b\u00fafer basado en pila, lo que podr\u00eda permitir ejecuci\u00f3n remota de c\u00f3digo o ca\u00edda del dispositivo afectado." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "COMPLETE", "baseScore": 9.0 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 8.5, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-119" } ] }, { "source": "ics-cert@hq.dhs.gov", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-121" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cbe_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.5", "matchCriteriaId": "B5962575-2692-4BE9-A2ED-0876266FE32D" }, { "vulnerable": true, "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cbeh_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.5", "matchCriteriaId": "B0EF5A0F-70CF-45DA-9059-71897B80CA67" }, { "vulnerable": true, "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cm25e_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.5", "matchCriteriaId": "E315B2C5-B4F7-4E40-BB34-8DF025DA6E21" }, { "vulnerable": true, "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cm55e_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.5", "matchCriteriaId": "D0F51CA0-E22C-4200-96A5-E726766F9072" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:fatek:plc_ethernet_module:-:*:*:*:*:*:*:*", "matchCriteriaId": "86322EB5-ED30-4FC3-9810-CC11F38246A8" } ] } ] } ], "references": [ { "url": "http://www.securityfocus.com/bid/96892", "source": "ics-cert@hq.dhs.gov", "tags": [ "VDB Entry", "Third Party Advisory" ] }, { "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-073-01", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ] } ] }