{ "id": "CVE-2019-17128", "sourceIdentifier": "cve@mitre.org", "published": "2019-10-09T16:15:15.233", "lastModified": "2019-10-11T19:48:27.617", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Netreo OmniCenter through 12.1.1 allows unauthenticated SQL Injection (Boolean Based Blind) in the redirect parameters and parameter name of the login page through a GET request. The injection allows an attacker to read sensitive information from the database used by the application." }, { "lang": "es", "value": "Netreo OmniCenter versiones hasta 12.1.1, permite una inyecci\u00f3n SQL no autenticada (Boolean Based Blind) en los par\u00e1metros de redireccionamiento y el nombre del par\u00e1metro de la p\u00e1gina login por medio de una petici\u00f3n GET. La inyecci\u00f3n permite a un atacante leer informaci\u00f3n confidencial desde la base de datos usada por la aplicaci\u00f3n." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 10.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-89" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:netreo:omnicenter:*:*:*:*:*:*:*:*", "versionEndIncluding": "12.1.1", "matchCriteriaId": "CC1228E9-10F0-4810-B6C8-CB3D0CDF6AFB" } ] } ] } ], "references": [ { "url": "http://packetstormsecurity.com/files/154763/OmniCenter-12.1.1-SQL-Injection.html", "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "VDB Entry" ] }, { "url": "https://www.netreo.com/blog/omnicenter-12-now-available-extensible-integration-unlimited-scalability-device-grouping/", "source": "cve@mitre.org", "tags": [ "Product" ] } ] }