{ "id": "CVE-2024-2424", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2024-04-15T22:15:08.657", "lastModified": "2025-02-25T18:56:27.037", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nAn input validation vulnerability exists in the Rockwell Automation\u00a05015-AENFTXT that causes the secondary adapter to result in a major nonrecoverable fault (MNRF) when malicious input is entered. If exploited, the availability of the device will be impacted, and a manual restart is required. Additionally, a malformed PTP packet is needed to exploit this vulnerability. \n\n" }, { "lang": "es", "value": "Existe una vulnerabilidad de validaci\u00f3n de entrada en Rockwell Automation 5015-AENFTXT que hace que el adaptador secundario genere una falla mayor no recuperable (MNRF) cuando se ingresa una entrada maliciosa. Si se explota, la disponibilidad del dispositivo se ver\u00e1 afectada y ser\u00e1 necesario reiniciarlo manualmente. Adem\u00e1s, se necesita un paquete PTP con formato incorrecto para aprovechar esta vulnerabilidad." } ], "metrics": { "cvssMetricV31": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-20" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:rockwellautomation:5015-aenftxt_firmware:2.011:*:*:*:*:*:*:*", "matchCriteriaId": "436F7BB7-A8CA-4E00-9F42-6DDB0D995E09" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:rockwellautomation:5015-aenftxt:-:*:*:*:*:*:*:*", "matchCriteriaId": "C699B471-D2E4-4B2F-B0A4-6045B8170354" } ] } ] } ], "references": [ { "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1667.html", "source": "PSIRT@rockwellautomation.com", "tags": [ "Broken Link", "Vendor Advisory" ] }, { "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1667.html", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Vendor Advisory" ] } ] }