{ "id": "CVE-2024-33606", "sourceIdentifier": "ics-cert@hq.dhs.gov", "published": "2024-06-11T21:15:53.050", "lastModified": "2025-03-01T02:04:54.647", "vulnStatus": "Undergoing Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "An attacker could retrieve sensitive files (medical images) as well as plant new medical images or overwrite existing medical images on a MicroDicom DICOM Viewer system. User interaction is required to exploit this vulnerability." }, { "lang": "es", "value": "Un atacante podr\u00eda recuperar archivos confidenciales (im\u00e1genes m\u00e9dicas), as\u00ed como colocar nuevas im\u00e1genes m\u00e9dicas o sobrescribir im\u00e1genes m\u00e9dicas existentes en un sistema MicroDicom DICOM Viewer. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad." } ], "metrics": { "cvssMetricV40": [ { "source": "ics-cert@hq.dhs.gov", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 8.6, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "ACTIVE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnAvailabilityImpact": "HIGH", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirement": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "availabilityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED" } } ], "cvssMetricV31": [ { "source": "ics-cert@hq.dhs.gov", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "baseScore": 8.8, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "ics-cert@hq.dhs.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-939" } ] }, { "source": "nvd@nist.gov", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-862" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:microdicom:dicom_viewer:*:*:*:*:*:*:*:*", "versionEndExcluding": "2024.2", "matchCriteriaId": "0070E07D-40B8-4DAA-9F84-79EEEF2DDB28" } ] } ] } ], "references": [ { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-163-01", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ] }, { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-163-01", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ] } ] }