{ "id": "CVE-2011-4860", "sourceIdentifier": "cve@mitre.org", "published": "2011-12-17T11:55:12.307", "lastModified": "2011-12-19T19:03:04.233", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a (1) ARP request message or (2) Neighbor Solicitation message." }, { "lang": "es", "value": "La funci\u00f3n ComputePassword del m\u00f3dulo Schneider Electric Quantum Ethernet del dispositivo NOE 771 (modulo Quantum 140NOE771*) genera la contrase\u00f1a de la cuenta fwupgrade realizando un c\u00e1lculo con la direcci\u00f3n MAC, lo que facilita a atacantes remotos obtener acceso a trav\u00e9s de (1) un mensaje de petici\u00f3n ARP o (2) un mensaje de descubrimiento de elementos en la misma red (\"Neighbor Solicitation\")." } ], "metrics": { "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "availabilityImpact": "COMPLETE", "baseScore": 10.0 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 10.0, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-287" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77100:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.3", "matchCriteriaId": "3E2B9B12-772E-45B0-B696-9487C5EC9669" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77100:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.4", "matchCriteriaId": "84E9206F-0AED-4C42-849E-F8741C070234" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77101:*:*:*:*:*:*:*:*", "versionEndIncluding": "4.9", "matchCriteriaId": "C6272D36-A9E3-4210-8998-19D65323E085" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77111:*:*:*:*:*:*:*:*", "versionEndIncluding": "5.0", "matchCriteriaId": "0780C449-C9A7-4D83-9090-C48EB308F69F" } ] } ] } ], "references": [ { "url": "http://reversemode.com/index.php?option=com_content&task=view&id=80&Itemid=1", "source": "cve@mitre.org" } ] }