{ "id": "CVE-2020-35789", "sourceIdentifier": "cve@mitre.org", "published": "2020-12-30T00:15:13.690", "lastModified": "2021-07-21T11:39:23.747", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "NETGEAR NMS300 devices before 1.6.0.27 are affected by command injection by an authenticated user." }, { "lang": "es", "value": "Los dispositivos NETGEAR NMS300 versiones anteriores a 1.6.0.27, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 }, { "source": "cve@mitre.org", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 6.5 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-20" }, { "lang": "en", "value": "CWE-78" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:nms300_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.6.0.27", "matchCriteriaId": "F7B5AF6D-6518-4FF2-9764-3680723D9897" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:nms300:-:*:*:*:*:*:*:*", "matchCriteriaId": "21056A06-415F-4161-8DA5-FEBC4460D94C" } ] } ] } ], "references": [ { "url": "https://kb.netgear.com/000062686/Security-Advisory-for-Post-Authentication-Command-Injection-on-NMS300-PSV-2020-0559", "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ] } ] }