{ "id": "CVE-2021-33841", "sourceIdentifier": "cve-coordination@incibe.es", "published": "2021-06-09T12:15:07.893", "lastModified": "2021-06-21T19:27:50.607", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges." }, { "lang": "es", "value": "Un dispositivo SGE-PLC1000, en su versi\u00f3n de firmware 0.9.2b, no maneja algunas petici\u00f3nes correctamente, permitiendo a un atacante remoto inyectar c\u00f3digo en el sistema operativo con m\u00e1ximos privilegios" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 }, { "source": "cve-coordination@incibe.es", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 2.8, "impactScore": 6.0 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "availabilityImpact": "COMPLETE", "baseScore": 10.0 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 10.0, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-78" } ] }, { "source": "cve-coordination@incibe.es", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-78" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*", "matchCriteriaId": "5D6B02E0-DE36-45F5-AD3D-908E30548661" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D" } ] } ] } ], "references": [ { "url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-os-command-injection", "source": "cve-coordination@incibe.es", "tags": [ "Third Party Advisory" ] } ] }