{ "id": "CVE-2021-41032", "sourceIdentifier": "psirt@fortinet.com", "published": "2022-05-04T16:15:08.170", "lastModified": "2022-07-12T17:42:04.277", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "An improper access control vulnerability [CWE-284] in FortiOS versions 6.4.8 and prior and 7.0.3 and prior may allow an authenticated attacker with a restricted user profile to gather sensitive information and modify the SSL-VPN tunnel status of other VDOMs using specific CLI commands." }, { "lang": "es", "value": "Una vulnerabilidad de control de acceso inapropiado [CWE-284] en FortiOS versiones 6.4.8 y anteriores y 7.0.3 y anteriores, puede permitir a un atacante autenticado con un perfil de usuario restringido recopilar informaci\u00f3n confidencial y modificar el estado del t\u00fanel SSL-VPN de otros VDOMs usando comandos CLI espec\u00edficos" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 2.5 }, { "source": "psirt@fortinet.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 3.4 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE", "baseScore": 5.5 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 4.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "versionStartIncluding": "6.2.0", "versionEndExcluding": "6.4.9", "matchCriteriaId": "63C336ED-54FA-4354-95AB-61C675BE30E6" }, { "vulnerable": true, "criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "versionStartIncluding": "7.0.0", "versionEndExcluding": "7.0.4", "matchCriteriaId": "30F10D70-1176-4119-BF1A-C2A5FCA386D4" } ] } ] } ], "references": [ { "url": "https://fortiguard.com/psirt/FG-IR-21-147", "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ] } ] }