{ "id": "CVE-2017-9962", "sourceIdentifier": "cybersecurity@se.com", "published": "2017-09-26T01:29:04.037", "lastModified": "2024-11-21T03:37:15.633", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected behavior. Client applications affected include ViewX and the Server Icon." }, { "lang": "es", "value": "Las versiones anteriores a agosto 2017 de ClearSCADA de Schneider Electric son susceptibles a una vulnerabilidad de asignaci\u00f3n de memoria en la que se podr\u00edan enviar peticiones mal formadas a las aplicaciones cliente de ClearSCADA para provocar un comportamiento inesperado. Las aplicaciones cliente afectadas son ViewX y el icono de servidor." } ], "metrics": { "cvssMetricV30": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "baseScore": 5.0, "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "PARTIAL" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 10.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-119" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:aveva:clearscada:*:*:*:*:*:*:*:*", "versionEndIncluding": "2010", "matchCriteriaId": "DAF38D64-EC72-4D39-80BB-4B3958C18B8B" } ] } ] } ], "references": [ { "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-264-01/", "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Vendor Advisory" ] }, { "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-264-01/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ] } ] }