{ "id": "CVE-2024-4081", "sourceIdentifier": "security@ni.com", "published": "2024-07-23T14:15:14.837", "lastModified": "2024-07-24T12:55:13.223", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions." }, { "lang": "es", "value": " Un problema de corrupci\u00f3n de memoria debido a una verificaci\u00f3n de longitud inadecuada en NI LabVIEW puede revelar informaci\u00f3n o resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2024 Q1 y versiones anteriores." } ], "metrics": { "cvssMetricV40": [ { "source": "security@ni.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "attackVector": "LOCAL", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "ACTIVE", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH", "vulnerableSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "subsequentSystemAvailability": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "baseScore": 8.4, "baseSeverity": "HIGH" } } ], "cvssMetricV31": [ { "source": "security@ni.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "security@ni.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-119" } ] } ], "references": [ { "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html", "source": "security@ni.com" } ] }