{ "id": "CVE-2024-36359", "sourceIdentifier": "security@trendmicro.com", "published": "2024-06-10T22:15:11.413", "lastModified": "2025-03-18T16:15:21.627", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A cross-site scripting (XSS) vulnerability in Trend Micro InterScan Web Security Virtual Appliance (IWSVA) 6.5 could allow an attacker to escalate privileges on affected installations.\r\n\r\nPlease note: an attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability." }, { "lang": "es", "value": "Una vulnerabilidad de Cross-Site Scripting (XSS) en Trend Micro InterScan Web Security Virtual Appliance (IWSVA) 6.5 podr\u00eda permitir a un atacante escalar privilegios en las instalaciones afectadas. Tenga en cuenta: un atacante primero debe obtener la capacidad de ejecutar c\u00f3digo con pocos privilegios en el sistema de destino para poder explotar esta vulnerabilidad." } ], "metrics": { "cvssMetricV31": [ { "source": "security@trendmicro.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "baseScore": 5.4, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.3, "impactScore": 2.7 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "baseScore": 5.4, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.3, "impactScore": 2.7 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-79" } ] }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-79" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:trendmicro:interscan_web_security_virtual_appliance:6.5:*:*:*:*:*:*:*", "matchCriteriaId": "1173BDF5-ADEB-49D5-B5B9-A911AF171179" } ] } ] } ], "references": [ { "url": "https://success.trendmicro.com/dcx/s/solution/000298065", "source": "security@trendmicro.com", "tags": [ "Broken Link" ] }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-574/", "source": "security@trendmicro.com", "tags": [ "Third Party Advisory", "VDB Entry" ] }, { "url": "https://success.trendmicro.com/dcx/s/solution/000298065", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ] }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-574/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ] } ] }