{ "id": "CVE-2024-49558", "sourceIdentifier": "security_alert@emc.com", "published": "2024-11-12T04:15:06.243", "lastModified": "2024-11-15T17:35:54.480", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Privilege Management vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges." }, { "lang": "es", "value": "El software Dell SmartFabric OS10, versiones 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contiene una vulnerabilidad de administraci\u00f3n de privilegios incorrecta. Un atacante con pocos privilegios y acceso local podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda una elevaci\u00f3n de privilegios." } ], "metrics": { "cvssMetricV31": [ { "source": "security_alert@emc.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "security_alert@emc.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-269" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*", "versionStartIncluding": "10.5.4.0", "versionEndExcluding": "10.5.4.13", "matchCriteriaId": "0938D211-024F-4794-90D1-A34F19ACD70F" }, { "vulnerable": true, "criteria": "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*", "versionStartIncluding": "10.5.5.0", "versionEndExcluding": "10.5.5.12", "matchCriteriaId": "22D34ABF-8002-42DE-8E21-DC66AF548F29" }, { "vulnerable": true, "criteria": "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*", "versionStartIncluding": "10.5.6.0", "versionEndExcluding": "10.5.6.6", "matchCriteriaId": "BB6E5BA8-71D2-4908-9B2B-CEDA754654B6" } ] } ] } ], "references": [ { "url": "https://www.dell.com/support/kbdoc/en-us/000247217/dsa-2024-425-security-update-for-dell-networking-os10-vulnerabilities", "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ] } ] }