{ "id": "CVE-2022-29834", "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "published": "2022-07-20T17:15:08.043", "lastModified": "2024-11-21T06:59:46.827", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS GENESIS64 versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 mobile monitoring application and accessing the monitoring screen." }, { "lang": "es", "value": "La vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta a un Directorio Restringido (\"Salto de Ruta\") en ICONICS GENESIS64 versiones 10.97 a 10.97.1, permite a un atacante remoto no autenticado acceder a archivos arbitrarios en el servidor de GENESIS64 y divulgar informaci\u00f3n almacenada en los archivos al insertar un par\u00e1metro de URL malicioso en la URL de la pantalla de monitorizaci\u00f3n entregada a la aplicaci\u00f3n de monitorizaci\u00f3n m\u00f3vil GENESIS64 y acceder a la pantalla de monitorizaci\u00f3n" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*", "matchCriteriaId": "44D3F652-C916-4395-BD11-AECDDF960D45" }, { "vulnerable": true, "criteria": "cpe:2.3:a:iconics:genesis64:10.97.1:*:*:*:*:*:*:*", "matchCriteriaId": "6D89798E-910C-4C3F-9385-D9B7CA921091" } ] } ] } ], "references": [ { "url": "https://jvn.jp/vu/JVNVU96480474/index.html", "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ] }, { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf", "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ] }, { "url": "https://jvn.jp/vu/JVNVU96480474/index.html", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ] }, { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ] } ] }