"id": "CVE-2024-7517",
|
|
"sourceIdentifier": "sirt@brocade.com",
|
|
"published": "2024-11-21T11:15:35.990",
|
|
"lastModified": "2024-11-21T13:57:24.187",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.\n\nThis specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Una vulnerabilidad de inyecci\u00f3n de comandos en Brocade Fabric OS anterior a la versi\u00f3n 9.2.0c y de la 9.2.1 a la 9.2.1a en plataformas de extensi\u00f3n IP podr\u00eda permitir que un atacante autenticado local realice una escalada de privilegios mediante el uso manipulado del comando portcfg. Esta explotaci\u00f3n espec\u00edfica solo es posible en plataformas de extensi\u00f3n IP: Brocade 7810, Brocade 7840, Brocade 7850 y en directores Brocade X6 o X7 con un blade de extensi\u00f3n SX-6 instalado. El atacante debe iniciar sesi\u00f3n en el conmutador a trav\u00e9s de SSH o una consola serial para realizar el ataque."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "sirt@brocade.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
|
|
"baseScore": 8.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"vulnerableSystemConfidentiality": "HIGH",
|
|
"vulnerableSystemIntegrity": "HIGH",
|
|
"vulnerableSystemAvailability": "HIGH",
|
|
"subsequentSystemConfidentiality": "NONE",
|
|
"subsequentSystemIntegrity": "NONE",
|
|
"subsequentSystemAvailability": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirements": "NOT_DEFINED",
|
|
"integrityRequirements": "NOT_DEFINED",
|
|
"availabilityRequirements": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
|
|
"safety": "NOT_DEFINED",
|
|
"automatable": "NOT_DEFINED",
|
|
"recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "sirt@brocade.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-77"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25071",
|
|
"source": "sirt@brocade.com"
|
|
}
|
|
]
|
|
} |