2024-07-14 02:06:08 +00:00

145 lines
4.7 KiB
JSON

{
"id": "CVE-2019-19292",
"sourceIdentifier": "productcert@siemens.com",
"published": "2020-03-10T20:15:19.243",
"lastModified": "2024-01-09T10:15:11.703",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\nAn authenticated remote attacker could exploit this vulnerability to\nread or modify the CCS database and potentially execute administrative\ndatabase operations or operating system commands."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Control Center Server (CCS) (Todas las versiones anteriores a V1.5.0). El Servidor de Control Center (CCS) contiene una vulnerabilidad de inyecci\u00f3n SQL en su protocolo de comunicaci\u00f3n basado en XML tal y como se proporciona por defecto en los puertos 5444/tcp y 5440/tcp. Un atacante remoto autenticado podr\u00eda aprovechar esta vulnerabilidad para leer o modificar la base de datos del CCS y ejecutar potencialmente operaciones administrativas de la base de datos o comandos del sistema operativo"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*",
"matchCriteriaId": "16668E9A-2D0A-425E-87F4-18CFC50551D3"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0F21BB6D-BFE0-4B69-97F2-1A871A390B1E"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf",
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Vendor Advisory"
]
}
]
}