mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 17:21:36 +00:00
115 lines
3.3 KiB
JSON
115 lines
3.3 KiB
JSON
{
|
|
"id": "CVE-2023-37248",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2023-07-11T10:15:11.680",
|
|
"lastModified": "2023-07-18T15:03:03.557",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21155)"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2201",
|
|
"versionEndExcluding": "2201.0008",
|
|
"matchCriteriaId": "0E8C9093-BD78-4ECE-9221-A889371B3839"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2302",
|
|
"versionEndExcluding": "2302.0002",
|
|
"matchCriteriaId": "C7103507-EE73-42FF-9DAB-37DD06467591"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |