2024-07-14 02:06:08 +00:00

101 lines
3.1 KiB
JSON

{
"id": "CVE-2023-40729",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-09-12T10:15:29.307",
"lastModified": "2023-09-14T17:00:59.243",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application lacks security control to prevent unencrypted communication without HTTPS. An attacker who managed to gain machine-in-the-middle position could manipulate, or steal confidential information."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en QMS Automotive (Todas las versiones &lt; V12.39). La aplicaci\u00f3n afectada carece de control de seguridad para evitar comunicaciones no cifradas sin HTTPS. Un atacante que lograra obtener la posici\u00f3n intermedia de la m\u00e1quina podr\u00eda manipular o robar informaci\u00f3n confidencial."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 7.4,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.2,
"impactScore": 5.2
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 7.3,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.1,
"impactScore": 5.2
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:qms_automotive:*:*:*:*:*:*:*:*",
"versionEndExcluding": "12.39",
"matchCriteriaId": "17162BBB-9C4B-4347-B2F6-F8E40D67C954"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}