"id": "CVE-2023-45601",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2023-10-10T11:15:13.247",
|
|
"lastModified": "2023-10-12T00:44:25.833",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)"
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en Parasolid V35.0 (Todas las versiones < V35.0.262), \nParasolid V35.1 (Todas las versiones < V35.1.250), \nParasolid V36.0 (Todas las versiones < V36.0.169), \nTecnomatix Plant Simulation V2201 ( Todas las versiones < V2201.0009),\nTecnomatix Plant Simulator V2302 (Todas las versiones < V2302.0003). \nLas aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de pila al analizar archivos IGS especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21290)"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-121"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "35.0",
|
|
"versionEndExcluding": "35.0.262",
|
|
"matchCriteriaId": "1C96074D-757B-4A3F-8B04-504D52DBE0EE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "35.1",
|
|
"versionEndExcluding": "35.1.250",
|
|
"matchCriteriaId": "78258279-F7F6-4057-8AE2-AF64387B04BB"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "36.0",
|
|
"versionEndExcluding": "36.0.169",
|
|
"matchCriteriaId": "97086FB9-6392-4B6D-8CD4-EA780AE4DD05"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2201",
|
|
"versionEndExcluding": "2201.0009",
|
|
"matchCriteriaId": "ECCC6F17-BB3D-4FD0-B277-5DD86EB4C9F7"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2302",
|
|
"versionEndExcluding": "2302.0003",
|
|
"matchCriteriaId": "C29307AD-B728-41D3-9D57-FD5D1D51ACFA"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |