2024-07-14 02:06:08 +00:00

162 lines
4.7 KiB
JSON

{
"id": "CVE-2023-4744",
"sourceIdentifier": "cna@vuldb.com",
"published": "2023-09-04T00:15:07.463",
"lastModified": "2024-05-17T02:31:45.953",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability."
},
{
"lang": "es",
"value": "Una vulnerabilidad declarada como cr\u00edtica ha sido encontrada en Tenda AC8 16.03.34.06_cn_TDC01. La funci\u00f3n afectada por esta vulnerabilidad es formSetDeviceName. La manipulaci\u00f3n conduce a un desbordamiento del b\u00fafer. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-238633."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "cna@vuldb.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
"matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80"
}
]
}
]
}
],
"references": [
{
"url": "https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md",
"source": "cna@vuldb.com",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "https://vuldb.com/?ctiid.238633",
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://vuldb.com/?id.238633",
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory"
]
}
]
}