2024-09-09 16:03:19 +00:00

119 lines
3.4 KiB
JSON

{
"id": "CVE-2023-50181",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2024-07-09T16:15:03.853",
"lastModified": "2024-09-09T15:59:57.527",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An improper access control vulnerability [CWE-284] in Fortinet FortiADC version 7.4.0 through 7.4.1 and before 7.2.4 allows a read only authenticated attacker to perform some write actions via crafted HTTP or HTTPS requests."
},
{
"lang": "es",
"value": "Una vulnerabilidad de control de acceso inadecuado [CWE-284] en Fortinet FortiADC versi\u00f3n 7.4.0 a 7.4.1 y anteriores a 7.2.4 permite que un atacante autenticado de solo lectura realice algunas acciones de escritura a trav\u00e9s de solicitudes HTTP o HTTPS manipuladas."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
},
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
},
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiadc:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.0.0",
"versionEndExcluding": "7.2.5",
"matchCriteriaId": "BABB446D-C65D-410D-95FA-7160C1853858"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiadc:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.4.0",
"versionEndExcluding": "7.4.2",
"matchCriteriaId": "0DAB820D-CA1F-4C05-9897-4DEF5A6E21AD"
}
]
}
]
}
],
"references": [
{
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-23-469",
"source": "psirt@fortinet.com",
"tags": [
"Vendor Advisory"
]
}
]
}