2024-09-04 16:03:36 +00:00

150 lines
4.7 KiB
JSON

{
"id": "CVE-2023-5913",
"sourceIdentifier": "security@opentext.com",
"published": "2023-11-08T17:15:08.193",
"lastModified": "2024-09-04T14:35:08.320",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Incorrect Privilege Assignment vulnerability in opentext Fortify ScanCentral DAST. The\u00a0vulnerability could be exploited to gain elevated privileges.This issue affects Fortify ScanCentral DAST versions 21.1, 21.2, 21.2.1, 22.1, 22.1.1, 22.2, 23.1.\n\n"
},
{
"lang": "es",
"value": "Vulnerabilidad de asignaci\u00f3n de privilegios incorrecta en texto abierto Fortify ScanCentral DAST. La vulnerabilidad podr\u00eda aprovecharse para obtener privilegios elevados. Este problema afecta a Fortify ScanCentral DAST versiones 21.1, 21.2, 21.2.1, 22.1, 22.1.1, 22.2, 23.1."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "security@opentext.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
},
{
"source": "security@opentext.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-266"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-266"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:microfocus:fortify_scancentral_dast:21.1:*:*:*:*:*:*:*",
"matchCriteriaId": "5578907C-9142-461B-88F3-D4510D57E23A"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:microfocus:fortify_scancentral_dast:21.2:*:*:*:*:*:*:*",
"matchCriteriaId": "DDE09FF8-AFDD-4F5E-AF44-FFE8854F5763"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:microfocus:fortify_scancentral_dast:21.2.1:*:*:*:*:*:*:*",
"matchCriteriaId": "8EF4C5A3-E698-469A-A8AB-223AC6013B1C"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:microfocus:fortify_scancentral_dast:22.1:*:*:*:*:*:*:*",
"matchCriteriaId": "0926D3A0-76B2-435C-B691-58B51EDF81B7"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:microfocus:fortify_scancentral_dast:22.1.1:*:*:*:*:*:*:*",
"matchCriteriaId": "956F2EB1-BF27-4F42-A325-E9F91EF60E5D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:microfocus:fortify_scancentral_dast:22.2:*:*:*:*:*:*:*",
"matchCriteriaId": "6DA67A67-DC1E-4FC0-8A9B-8A2192E939BB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:microfocus:fortify_scancentral_dast:23.1:*:*:*:*:*:*:*",
"matchCriteriaId": "9BFD11CE-87C4-40A2-A6EA-80CF1D465F4B"
}
]
}
]
}
],
"references": [
{
"url": "https://portal.microfocus.com/s/article/KM000023500?language=en_US",
"source": "security@opentext.com",
"tags": [
"Vendor Advisory"
]
}
]
}