"id": "CVE-2018-12257",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2018-06-12T18:29:00.537",
|
|
"lastModified": "2024-11-21T03:44:52.353",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An issue was discovered on Momentum Axel 720P 5.1.8 devices. There is Authenticated Custom Firmware Upgrade via DNS Hijacking. An authenticated root user with CLI access is able to remotely upgrade firmware to a custom image due to lack of SSL validation by changing the nameservers in /etc/resolv.conf to the attacker's server, and serving the expected HTTPS response containing new firmware for the device to download."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha descubierto un problema en dispositivos Momentum Axel 720P 5.1.8. Hay una actualizaci\u00f3n de firmware personalizada autenticada mediante el secuestro de DNS. Un usuario root autenticado con acceso a la interfaz de l\u00ednea de comandos puede actualizar remotamente el firmware con una imagen personalizada debido a la falta de validaci\u00f3n SSL mediante el cambio de los servidores de nombre en /etc/resolv.conf en el servidor del atacante y sirviendo la respuesta HTTPS esperada que contiene nuevo firmware para que descargue el dispositivo."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
|
|
"baseScore": 4.4,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 0.8,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N",
|
|
"baseScore": 2.1,
|
|
"accessVector": "LOCAL",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"baseSeverity": "LOW",
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-295"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:apollotechnologiesinc:momentum_axel_720p_firmware:5.1.8:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0E6C0B73-09F5-4564-95B1-8D6EE44510B6"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:apollotechnologiesinc:momentum_axel_720p:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "BE5DCE62-31E9-4C78-A4E4-88000392C7A2"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://rchase.com/downloads/momentum-iot-penetration-test-report.pdf",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://rchase.com/downloads/momentum-iot-penetration-test-report.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |