René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

108 lines
3.3 KiB
JSON

{
"id": "CVE-2011-4055",
"sourceIdentifier": "cret@cert.org",
"published": "2012-01-08T00:55:01.893",
"lastModified": "2017-08-29T01:30:26.817",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL."
},
{
"lang": "es",
"value": "Desbordamiento de b\u00fafer en el control ActiveX WebClient en Siemens Tecnomatix FactoryLink v6.6.1 (aka 6.6 SP1), v7.5.217 (aka 7.5 SP2), y v8.0.2.54 permite a atacantes remotos ejecutar c\u00f3digo de su elecci\u00f3n a trav\u00e9s de una cadena demasiado larga en un par\u00e1metro asociado con la direcci\u00f3n URL."
}
],
"metrics": {
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:tecnomatix_factorylink:6.6.1:*:*:*:*:*:*:*",
"matchCriteriaId": "BD04B4F4-C398-4583-AEC3-3F7F43EC65B4"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:tecnomatix_factorylink:7.5.217:*:*:*:*:*:*:*",
"matchCriteriaId": "0E0DAE9F-786D-4408-93ED-25E75EB598C4"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:tecnomatix_factorylink:8.0.2.54:*:*:*:*:*:*:*",
"matchCriteriaId": "FD7211D4-AE67-42B3-BC4F-7F8E5C685123"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/51266",
"source": "cret@cert.org"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-343-01.pdf",
"source": "cret@cert.org",
"tags": [
"US Government Resource"
]
},
{
"url": "http://www.usdata.com/sea/factorylink/en/p_nav5.asp",
"source": "cret@cert.org",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72117",
"source": "cret@cert.org"
}
]
}