"id": "CVE-2011-4513",
|
|
"sourceIdentifier": "cret@cert.org",
|
|
"published": "2012-02-03T20:55:01.513",
|
|
"lastModified": "2012-02-06T05:00:00.000",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Siemens WinCC flexible 2004, 2005, 2007 y 2008; WinCC V11 (TIA portal); TP, OP, MP, Comfort Panels y Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced y WinCC flexible Runtime permiten a atacantes remotos asistidos por el usuario ejecutar c\u00f3digo arbitrario a trav\u00e9s de un archivo de proyecto, relacionado con un servidor web y el cargador de tiempo de ejecuci\u00f3n (\"runtime loader\")."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 10.0
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-noinfo"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7D596C29-36F8-44F2-897D-FD107769E5A9"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "2D84E29A-4BC2-4229-83C3-D9F7A641D19C"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9B3ADDE1-1F91-43E7-A3C3-3069916F4B23"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "1432EC7A-47B2-41D1-B90B-72DBB79AC266"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "18A9883B-80E1-4B2E-88DA-D2326AE3DC08"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "DC593746-B329-43EA-8CA1-AA56AC5A3B10"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "442AC914-BDD5-4D0C-9E04-88F60EE2B730"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D9749966-1666-4F7D-90D0-17AFBB88AE83"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9471D239-08B1-4076-82F7-2B73F4E343CE"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "1AE3AE80-C7A2-4581-993A-536936F6D315"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
|
|
"source": "cret@cert.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
|
|
"source": "cret@cert.org",
|
|
"tags": [
|
|
"US Government Resource"
|
|
]
|
|
}
|
|
]
|
|
} |