René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

90 lines
3.0 KiB
JSON

{
"id": "CVE-2011-4515",
"sourceIdentifier": "cret@cert.org",
"published": "2013-03-21T14:55:01.423",
"lastModified": "2013-05-31T04:00:00.000",
"vulnStatus": "Analyzed",
"evaluatorImpact": "Per http://ics-cert.us-cert.gov/pdf/ICSA-13-079-03.pdf\r\n\r\nINSECURE PASWORD STORAGE\r\nUser credentials for the HMI\u2019s Web application are stored within the HMI\u2019s system. These data are obfuscated in a reversible way and arereadable and writable for users with physical access or Sm@rt Server access to the system.",
"descriptions": [
{
"lang": "en",
"value": "Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access."
},
{
"lang": "es",
"value": "Siemens WinCC (Portal TIA) 11 utiliza un algoritmo reversible para el almacenamiento de contrase\u00f1as de aplicaciones HMI Web en archivos legibles por todo el mundo escritura global, lo que permite a usuarios locales obtener informaci\u00f3n sensible mediante el aprovechamiento de (1) el acceso f\u00edsico o (2) servidor de acceso Sm@rt."
}
],
"metrics": {
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-255"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:wincc_tia_portal:11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "AA0630E4-BC67-46D1-90C5-8E5F3AAC86F4"
}
]
}
]
}
],
"references": [
{
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-079-03.pdf",
"source": "cret@cert.org",
"tags": [
"US Government Resource"
]
},
{
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-212483.pdf",
"source": "cret@cert.org",
"tags": [
"Vendor Advisory"
]
}
]
}