"id": "CVE-2017-14018",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2017-12-05T23:29:00.217",
"lastModified": "2019-10-09T23:23:44.407",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "An improper authentication issue was discovered in Johnson & Johnson Ethicon Endo-Surgery Generator Gen11, all versions released before November 29, 2017. The security authentication mechanism used between the Ethicon Endo-Surgery Generator Gen11 and single-patient use products can be bypassed, allowing for unauthorized devices to be connected to the generator, which could result in a loss of integrity or availability."
},
{
"lang": "es",
"value": "Se ha descubierto un problema de autenticaci\u00f3n indebida en Johnson Ethicon Endo-Surgery Generator Gen11, en todas las versiones lanzadas antes del 29 de noviembre de 2017. El mecanismo de autenticaci\u00f3n de seguridad empleado en Ethicon Endo-Surgery Generator Gen11 y en productos de uso para un solo paciente puede omitirse, permitiendo que dispositivos sin autorizaci\u00f3n se conecten al generador. Esto puede resultar en una p\u00e9rdida de integridad o disponibilidad."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:L",
"attackVector": "PHYSICAL",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.5,
"impactScore": 4.2
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:M/Au:N/C:N/I:P/A:P",
"accessVector": "LOCAL",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3
},
"baseSeverity": "LOW",
"exploitabilityScore": 3.4,
"impactScore": 4.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:ethicon:endo-surgery_generator_gen11_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41BE40E0-3AE7-498C-BEE9-F9B8886A0FC4"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:ethicon:endo-surgery_generator_gen11:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F123F258-704F-47C6-9089-5BC358649C03"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/101978",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-332-01",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"US Government Resource",
"Third Party Advisory"
]
}
]
}