René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

120 lines
3.4 KiB
JSON

{
"id": "CVE-2017-14454",
"sourceIdentifier": "talos-cna@cisco.com",
"published": "2023-01-12T00:15:08.627",
"lastModified": "2023-01-20T19:12:37.490",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Multiple exploitable buffer overflow vulnerabilities exists in the PubNub message handler for the \"control\" channel of Insteon Hub running firmware version 1012. Specially crafted replies received from the PubNub service can cause buffer overflows on a global section overwriting arbitrary data. An attacker should impersonate PubNub and answer an HTTPS GET request to trigger this vulnerability. The `strcpy` at [18] overflows the buffer `insteon_pubnub.channel_al`, which has a size of 16 bytes."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 6.0
}
],
"cvssMetricV30": [
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 6.0
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
},
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:insteon:hub_firmware:1012:*:*:*:*:*:*:*",
"matchCriteriaId": "17F98B37-72C0-48A5-A4E2-12327F48327E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:insteon:hub:-:*:*:*:*:*:*:*",
"matchCriteriaId": "951165BE-0AC1-4690-8B36-E402CA0197FB"
}
]
}
]
}
],
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0502",
"source": "talos-cna@cisco.com",
"tags": [
"Technical Description",
"Third Party Advisory"
]
}
]
}