René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

109 lines
3.4 KiB
JSON

{
"id": "CVE-2017-6673",
"sourceIdentifier": "ykramarz@cisco.com",
"published": "2017-06-13T06:29:01.127",
"lastModified": "2017-06-20T14:53:51.923",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in Cisco Firepower Management Center could allow an authenticated, remote attacker to obtain user information. An attacker could use this information to perform reconnaissance. More Information: CSCvc10894. Known Affected Releases: 6.1.0.2 6.2.0. Known Fixed Releases: 6.2.0."
},
{
"lang": "es",
"value": "Una vulnerabilidad en Cisco Firepower Management Center podr\u00eda permitir a un atacante remoto autenticado obtener informaci\u00f3n del usuario. Un atacante podr\u00eda usar esta informaci\u00f3n para realizar el reconocimiento. M\u00e1s informaci\u00f3n: CSCvc10894. Versiones afectadas conocidas: 6.1.0.2 y 6.2.0. Versiones solucionadas conocidas: 6.2.0."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:cisco:firepower_management_center:6.1.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "8AB6251C-F898-431C-B693-DF075B8808B6"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:cisco:firepower_management_center:6.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "9641FE9B-BC9F-472F-B53B-F4287EE2F17A"
}
]
}
]
}
],
"references": [
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170607-fmc",
"source": "ykramarz@cisco.com",
"tags": [
"Vendor Advisory"
]
}
]
}