mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
258 lines
8.1 KiB
JSON
258 lines
8.1 KiB
JSON
{
|
|
"id": "CVE-2018-11036",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2018-05-31T12:29:00.220",
|
|
"lastModified": "2018-08-01T18:39:38.587",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Ruckus SmartZone (formerly Virtual SmartCell Gateway or vSCG) 3.5.0, 3.5.1, 3.6.0, and 3.6.1 (Essentials and High Scale) on vSZ, SZ-100, SZ-300, and SCG-200 devices allows remote attackers to obtain sensitive information or modify data."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Ruckus SmartZone (anteriormente Virtual SmartCell Gateway o vSCG) 3.5.0, 3.5.1, 3.6.0 y 3.6.1 (Essentials y High Scale) en dispositivos vSZ, SZ-100, SZ-300 y SCG-200 permite a los atacantes remotos obtener informaci\u00f3n sensible o modificar datos."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 9.1,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.2
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 6.4
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 4.9,
|
|
"acInsufInfo": true,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-200"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9998987C-0AD2-4CDB-9511-2BC9462490AE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.5.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "EF9AF4FE-6115-4F24-B171-62A5DB74A6BC"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.6.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "71FD8B5B-EA1B-4ABA-B0A1-CF675F8765F5"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.6.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "38393B8A-E549-4C07-A73E-BEB6DEB08E6A"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:ruckuswireless:vsz:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "A1E9A46B-D8E4-489A-8648-28EDDF000E28"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AF021C98-2D73-48E3-AB05-F69C9D3AD569"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.5.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F95F4D57-D238-47E6-AAF7-8A19B18FC29C"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.6.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F7F0BA42-FF78-4F7D-AF63-C731B0C32DD2"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.6.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "CB65F202-22C7-4E57-8EF3-8BA1DE6A3BA3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:ruckuswireless:scg-200:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "B1BD8748-6B99-4218-8D76-3A6A5847DB25"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "45CEB61E-3E81-4F2D-B23E-8332E95C6C23"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.5.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FF91774B-2DE9-4478-AD17-D7C4477CE458"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.6.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AA61F6F5-591D-45D2-90B2-4096A60BB978"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.6.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9945DADB-81D0-407B-A8C1-FFA9B5A6B228"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:ruckuswireless:sz-300:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4087D2FB-0853-40AE-A03F-803B5972A404"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "ECB56AD5-AE22-4497-852B-EDB12E7B68BC"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.5.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "6AF9CED5-087A-475B-8A8D-C05F45ADEF57"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.6.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4C5A6C11-3349-448B-99E7-1A5AF17E4872"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.6.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0A116EBD-77CD-4F93-A1BB-56DDF64F2EA4"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:ruckuswireless:sz-100:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "3B9F3E41-79CA-45B7-B799-B0A64E60BA16"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.ruckuswireless.com/security/279/view/txt",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Mailing List",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |