mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 17:21:36 +00:00
134 lines
3.9 KiB
JSON
134 lines
3.9 KiB
JSON
{
|
|
"id": "CVE-2018-11078",
|
|
"sourceIdentifier": "security_alert@emc.com",
|
|
"published": "2018-09-11T19:29:01.520",
|
|
"lastModified": "2019-10-09T23:33:22.760",
|
|
"vulnStatus": "Modified",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Dell EMC VPlex GeoSynchrony, versions prior to 6.1, contains an Insecure File Permissions vulnerability. A remote authenticated malicious user could read from VPN configuration files on and potentially author a MITM attack on the VPN traffic."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Dell EMC VPlex GeoSynchrony, en versiones anteriores a la 6.1, contiene una vulnerabilidad de permisos inseguros. Un usuario malicioso autenticado remoto podr\u00eda leer desde los archivos de configuraci\u00f3n VPN y realizar un ataque Man-in-the-Middle (MitM) sobre el tr\u00e1fico de la VPN."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.6,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:N",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 4.0,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 0.9,
|
|
"impactScore": 2.7
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 6.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 6.8,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-732"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:dell:emc_vplex_geosynchrony:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "6.1",
|
|
"matchCriteriaId": "5410E458-35D8-49A9-94EF-F7EBB548C113"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://www.securitytracker.com/id/1041613",
|
|
"source": "security_alert@emc.com",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"VDB Entry"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://seclists.org/fulldisclosure/2018/Sep/10",
|
|
"source": "security_alert@emc.com",
|
|
"tags": [
|
|
"Mailing List",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |