"id": "CVE-2018-1212",
"sourceIdentifier": "security_alert@emc.com",
"published": "2018-07-02T17:29:00.257",
"lastModified": "2019-10-09T23:38:15.367",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "The web-based diagnostics console in Dell EMC iDRAC6 (Monolithic versions prior to 2.91 and Modular all versions) contains a command injection vulnerability. A remote authenticated malicious iDRAC user with access to the diagnostics console could potentially exploit this vulnerability to execute arbitrary commands as root on the affected iDRAC system."
},
{
"lang": "es",
"value": "La consola web de diagn\u00f3stico en Dell EMC iDRAC6 (versiones Monolithic anteriores a la 2.91 y Modular en todas las versiones) contiene una vulnerabilidad de inyecci\u00f3n de comandos. Un usuario iDRAC autenticado, remoto y malicioso con acceso a la consola de diagn\u00f3stico podr\u00eda explotar esta vulnerabilidad para ejecutar comandos arbitrarios como root en el sistema iDRAC afectado."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
},
{
"source": "security_alert@emc.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:idrac6_modular:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5A187ADC-E596-4B72-B8D6-D502702B5FC4"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:idrac6_monolithic:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.91",
"matchCriteriaId": "9E064ABF-3293-47EB-8D9F-860EBC88E64B"
}
]
}
]
}
],
"references": [
{
"url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20487494",
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
]
}
]
}