"id": "CVE-2018-13289",
|
|
"sourceIdentifier": "security@synology.com",
|
|
"published": "2019-04-01T15:29:00.560",
|
|
"lastModified": "2019-10-09T23:34:19.823",
|
|
"vulnStatus": "Modified",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Information exposure vulnerability in SYNO.FolderSharing.List in Synology Router Manager (SRM) before 1.1.7-6941-2 allows remote attackers to obtain sensitive information via the (1) folder_path or (2) real_path parameter."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Una vulnerabilidad de exposici\u00f3n de informaci\u00f3n en SYNO.FolderSharing.List en Synology Router Manager (SRM), en versiones anteriores a la 1.1.7-6941-2, permite a los atacantes remotos obtener informaci\u00f3n sensible mediante los par\u00e1metros (1) folder_path o (2) real_path."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 1.4
|
|
},
|
|
{
|
|
"source": "security@synology.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 1.4
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-200"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "security@synology.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-200"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:synology:router_manager:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "1.1",
|
|
"versionEndExcluding": "1.1.7-6941-2",
|
|
"matchCriteriaId": "CBD9335E-1B78-42F3-8053-6C39D7982C4A"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.synology.com/security/advisory/Synology_SA_18_48",
|
|
"source": "security@synology.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |