mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 01:02:25 +00:00
117 lines
3.4 KiB
JSON
117 lines
3.4 KiB
JSON
{
|
|
"id": "CVE-2018-15477",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2018-08-30T17:29:01.253",
|
|
"lastModified": "2018-11-09T15:46:46.607",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Los dispositivos myStrom WiFi Switch en versiones anteriores a la 2.66 no saneaba un par\u00e1metro recibido desde la nube que fue empleado en un comando del sistema operativo. Los servidores maliciosos eran capaces de ejecutar comandos del sistema operativo en el dispositivo."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 10.0
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:mystrom:wifi_switch_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.66",
|
|
"matchCriteriaId": "70FCB4DD-851D-4BC3-A21C-1FCD0EF98C96"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:mystrom:wifi_switch:v1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "BAA509BE-58A0-42ED-9443-315A476E56C8"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2018-15476ff.txt",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |