"id": "CVE-2018-7798",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2018-11-02T17:29:00.680",
|
|
"lastModified": "2022-01-31T20:31:39.940",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Existe una vulnerabilidad de verificaci\u00f3n insuficiente de autenticidad de datos (CWE-345) en Modicon Modicon M221, todas las versiones, lo que podr\u00eda provocar un cambio en la configuraci\u00f3n IPv4 (direcci\u00f3n IP, m\u00e1scara y puerta de enlace) al conectarse remotamente al dispositivo."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "LOW",
|
|
"baseScore": 8.2,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 4.2
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 6.4
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 4.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-345"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:somachine_basic:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "2BCEA269-6242-41FD-B141-F72CAFC8F114"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "BB0D83F4-B718-47AB-AFB8-B576CB138AAC"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://www.securityfocus.com/bid/105970",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"VDB Entry"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |