"id": "CVE-2021-21904",
|
|
"sourceIdentifier": "talos-cna@cisco.com",
|
|
"published": "2021-12-22T19:15:09.743",
|
|
"lastModified": "2022-08-31T19:15:19.780",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability"
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se presenta una vulnerabilidad de salto de directorio en el comando CMA CLI setenv de iC Module CMA de Garrett Metal Detectors versi\u00f3n 5.0. Un atacante puede proporcionar una entrada maliciosa para desencadenar esta vulnerabilidad"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "talos-cna@cisco.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.1,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 2.3,
|
|
"impactScore": 6.0
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 9.0
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 8.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-22"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "talos-cna@cisco.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-22"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356",
|
|
"source": "talos-cna@cisco.com",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |