"id": "CVE-2021-21905",
"sourceIdentifier": "talos-cna@cisco.com",
"published": "2021-12-22T19:15:09.797",
"lastModified": "2022-08-31T19:12:51.173",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called \u201cCMA Connect\u201d, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device."
},
{
"lang": "es",
"value": "Una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria se presenta en la forma en que es usada la funci\u00f3n CMA readfile de Garrett Metal Detectors iC Module Versi\u00f3n 5.0, en varios lugares. El Garrett iC Module expone una CLI autenticada a trav\u00e9s del puerto TCP 6877. Esta interfaz es usada por un cliente GUI secundario, llamado \"CMA Connect\", para interactuar con el iC Module en nombre del usuario. Despu\u00e9s de que un cliente sea autenticado con \u00e9xito, puede enviar comandos de texto plano para manipular el dispositivo"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.5,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.5
},
"baseSeverity": "HIGH",
"exploitabilityScore": 6.8,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318"
}
]
}
]
}
],
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357",
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}