"id": "CVE-2020-26078",
"sourceIdentifier": "ykramarz@cisco.com",
"published": "2020-11-18T18:15:11.903",
"lastModified": "2020-11-25T17:37:49.697",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the file system of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to overwrite files on an affected system. The vulnerability is due to insufficient file system protections. An attacker could exploit this vulnerability by crafting API requests and sending them to an affected system. A successful exploit could allow the attacker to overwrite files on an affected system."
},
{
"lang": "es",
"value": "Una vulnerabilidad en el sistema de archivos de Cisco IoT Field Network Director (FND), podr\u00eda permitir a un atacante remoto autenticado sobrescribir archivos en un sistema afectado. La vulnerabilidad es debido a una protecci\u00f3n insuficiente del sistema de archivos. Un atacante podr\u00eda explotar esta vulnerabilidad al dise\u00f1ar peticiones de API y envi\u00e1ndolas a un sistema afectado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante sobrescribir archivos en un sistema afectado"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.2,
"impactScore": 5.2
}
],
"cvssMetricV30": [
{
"source": "ykramarz@cisco.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
},
{
"source": "ykramarz@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-73"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.6.1",
"matchCriteriaId": "0D507A4F-4079-4B68-997E-88901E063348"
}
]
}
]
}
],
"references": [
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-OVW-SHzOE3Pd",
"source": "ykramarz@cisco.com",
"tags": [
"Vendor Advisory"
]
}
]
}