René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

143 lines
4.1 KiB
JSON

{
"id": "CVE-2020-35228",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-03-10T19:15:12.327",
"lastModified": "2021-03-17T18:40:01.083",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A cross-site scripting (XSS) vulnerability in the administration web panel on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices allows remote attackers to inject arbitrary web script or HTML via the language parameter."
},
{
"lang": "es",
"value": "Una vulnerabilidad de tipo cross-site scripting (XSS) en el panel de administraci\u00f3n web de los dispositivos NETGEAR JGS516PE/GS116Ev2 versi\u00f3n v2.6.0.43, permite a atacantes remotos inyectar c\u00f3digo web arbitrario o HTML por medio del par\u00e1metro language"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "SINGLE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE",
"baseScore": 3.5
},
"baseSeverity": "LOW",
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gs116e_firmware:2.6.0.43:*:*:*:*:*:*:*",
"matchCriteriaId": "2EE8AF63-BEAE-477C-A865-78727E0E1CDE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "6DA5EF92-9B28-4C81-8A95-C5BCEC19591A"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:jgs516pe_firmware:2.6.0.43:*:*:*:*:*:*:*",
"matchCriteriaId": "B8F3F57E-F184-4323-AA4D-9C8C57EDC94F"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DCBC0DAB-226E-4C95-9818-7758D37EFD10"
}
]
}
]
}
],
"references": [
{
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}