René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

116 lines
3.6 KiB
JSON

{
"id": "CVE-2020-8587",
"sourceIdentifier": "security-alert@netapp.com",
"published": "2021-02-08T22:15:12.327",
"lastModified": "2021-02-12T21:17:09.670",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "OnCommand System Manager 9.x versions prior to 9.3P20 and 9.4 prior to 9.4P3 are susceptible to a vulnerability that could allow HTTP clients to cache sensitive responses making them accessible to an attacker who has access to the system where the client runs."
},
{
"lang": "es",
"value": "OnCommand System Manager versiones 9.x anteriores a 9.3P20 y versiones 9.4 anteriores a 9.4P3, son susceptibles a una vulnerabilidad que podr\u00eda permitir a los clientes HTTP almacenar en cach\u00e9 respuestas confidenciales, haci\u00e9ndolas accesibles a un atacante que tenga acceso al sistema donde se ejecuta el cliente"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1
},
"baseSeverity": "LOW",
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:netapp:oncommand_system_manager:*:*:*:*:*:*:*:*",
"versionStartIncluding": "9.0",
"versionEndExcluding": "9.3",
"matchCriteriaId": "24FEA418-761F-4933-970E-E5AFDFAF5AB5"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:netapp:oncommand_system_manager:9.3:-:*:*:*:*:*:*",
"matchCriteriaId": "727729D1-2B05-4BA8-AC25-6CB376A03CCB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:netapp:oncommand_system_manager:9.4:-:*:*:*:*:*:*",
"matchCriteriaId": "100D6552-2471-4DCA-BA9A-9FD5FF91389E"
}
]
}
]
}
],
"references": [
{
"url": "https://security.netapp.com/advisory/NTAP-20210208-0001/",
"source": "security-alert@netapp.com",
"tags": [
"Vendor Advisory"
]
}
]
}